1-input- 4-output high accuracy 4-20mA signal isolation transmitter/ isolation amplifier / signal isolator---- from Shenzhen Jie Sheng Da Technology specialy supply, 1-input- 4-output high accuracy 4-20mA signal isolation transmitter/ isolation amplifier / signal isolator model: DIN35 1x4 MI-I3-P1-IO1 product size: 115X100X23mm
4-20mA signal isolation transmitter GENERAL DESCRIPTION:
JIE Sheng Technology DIN35 1x2 MI-V(I)x-Px-V(I)Ox active precision isolation transmitter is a signal conditioner with electrical insulation between input and output. It can receive a variety of analog signal from the field instrument, and transmit a standard output signal or user-specified special signal to the control room、PLC、PC or DCS. The product is isolated between power supply, input and output, the isolated voltage between them is up to 2500VDC .It is widely used in the industrial measurement systems, medical electronic equipment, electrical equipment etc. Adopting high efficiency electromagnetism isolation technology to achieve signal isolation, it is available to keep high output accuracy, good linearity and low temperature drift. Suitable for using in vibration, damp industrial field, the standard DIN35mm rail mounting for easy user installation.
isolation amplifier features:
● Small size, low cost, international standards DIN35mm rail mounting
● three-port isolation (input, output and power supply )
● 1-input- 2-output ,isolated between channels
● High accuracy (0.1% F.S, 0.2% F.S)
● High linearity (0.1% F.S)
● High isolation voltage (2500VDC/60S)
● Low temperature drift (35PPM / ℃)
● Wide Industrial class operation temperature (-45 ~ +85 ℃)
●High reliability (MTBF> 50 Wan hour)
●Power supply (5VDC/12VDC/15VDC/24VDC single power supply options)
●International standard signal input and output (0 ~ 5V / 1-5V/0 ~ 10V / 0 ~ ± 10V / 4 ~ 20mA / 0 ~ ± 20mA/0-100mV etc. optional)
Product Selection Parameter List:
|
DIN35
|
1x2
|
MI
|
V(I)x
|
Px
|
V(I)Ox
|
Detailed description
|
Package code
|
|
|
|
|
|
Standard DIN 35mm Package
|
Channel code
|
|
|
|
|
1-input-2-putput
|
Isolation code
|
|
|
|
Electromagnetism isolation
|
Current/voltage signal input code
|
V(I)1:
|
|
|
V1:0~5V I1:0~1mA
|
V(I)2:
|
|
|
V2:0~10V I2:0~10mA
|
V(I)3:
|
|
|
V3:0~75mV I3:0~20mA
|
V(I)4:
|
|
|
V4:0~2.5V I4:4~20mA
|
V(I)5:
|
|
|
V5:0~±5V I5:0~±1mA
|
V(I)6:
|
|
|
V6:0~±10V I6:0~±10mA
|
V(I)7:
|
|
|
V7:0~±100mV I7:0~±20mA
|
V(I)ud:
|
|
|
V(I)ud:User-defined
|
Power supply code
|
P1:
|
|
24VDC
|
P2:
|
|
15VDC
|
P3:
|
|
12VDC
|
P4:
|
|
5VDC
|
Pud:
|
|
User-defined
|
Current/voltage signal output code
|
IO1:
|
4~20mA
|
IO2:
|
0~20mA
|
IO3:
|
-20~+20mA
|
VO4:
|
0~5V
|
VO5:
|
0~10V
|
VO6:
|
1~5V
|
VO7:
|
0~±5V
|
VO8:
|
0~±10V
|
V(I)Oud:
|
V(I)Oud:User-defined
|
Note 1: When ordering ,please determine the input 、output and power parameters, if there are special requirements can be customized.
|
ELECTRICAL CHARACTERISTICS:
signs
|
Item
|
Test Condition
|
Min
|
Type
|
Max
|
Units
|
Isolation
Characteristics
|
Isolation voltage
|
AC,50Hz,(Tested for 1 minute humidity<70% ,leakage current < 1mA,)
|
|
2500
|
|
V(rms)
|
Transmission characteristics
|
Gain error
|
|
|
1
|
|
V/V
|
Gain drift
Non-linearity
|
|
|
35
|
|
ppm/℃
|
Non-linearity
|
|
|
0.1
|
0.2
|
%FSR
|
Input Characteristics
|
Signal input
|
voltage
|
|
0
|
|
15
|
V
|
current
|
|
0
|
|
30
|
mA
|
Input offset voltage
|
|
|
2
|
5
|
mV
|
Input impedance
|
voltage
|
|
|
1
|
|
M
|
current
|
|
|
|
50
|
Ω
|
Output Characteristics
|
Signal output
|
voltage
|
|
-10
|
|
10
|
V
|
current
|
|
-20
|
|
20
|
mA
|
Load capacity
|
voltage
|
Vout=10V
|
|
2
|
|
kΩ
|
current
|
|
0
|
350
|
500
|
Ω
|
Signal output ripple
|
Unfiltered
|
|
10
|
20
|
mVRMS
|
Power input Characteristics
|
Power supply
|
Voltage
|
|
3.3
|
12
|
24
|
VDC
|
Power loss
|
|
|
|
2
|
W
|
Rage
|
|
-10
|
|
+10
|
%
|
Other Characteris
|
Operating temperature
|
|
-45
|
|
85
|
℃
|
storage temperature
|
|
-55
|
|
105
|
℃
|
Weight
|
|
|
|
60
|
g
|
Note:
|
Normal load ≤ 350Ω, if required load 500Ω, please note when ordering 。
|